Chinese | Home | Contact us
 
 
 

 

 

HQ980 series thermal mass flow meter are introduce into America tech and research our Patent (patent No.: 98224228.X). and get the certification of explosion-proof (No.: GYB98463). Our product also pass country standard (JJG879-95). HQ980 flow meter direct mass flow measurement without the need for pressure or temperature correction and it become the most popular flow meter from all over the world.

type

HQ981in-line thermal mass flow

HQ983 insertion

medium

gas(except for acetylene)

accuracy

±0.5%,±1%

application

Iron, steel, chemicals, petroleum, metallurgy, paper, food, urban drainage and other industries

diameter

D6mm—300mm

D40mm—6000mm

flow velocity

0.0001—60m/s

range of pressure

<2.5MpaG(MAX<20MpaG)

signal output

4—20mA,<=500Ω,RS485,HARTcommunicatot

protect class

IP65、IP68

others

Protect class :DiiCT3, RS—232C& HQ—BUS,alarm,range ability 1:120(1:1000)